top of page

Office Acoustic Ceiling Panels: Specifying Sylo, Baff and Acoustic Stretch for Open-Plan Workplaces

4 minutes ago
6 min read

Open-plan offices are rarely too loud because people talk too much. They are too loud because the room returns every conversation to everyone in it. In most fit-outs the ceiling is the largest uninterrupted reflective surface on the floor plate, which makes it the most effective place to put absorption, and the decision that most shapes how the finished space sounds.

This guide sets out the four ceiling-level approaches NeviTec manufactures in Wellingborough, how they differ in build-up and certified performance, and where each one earns its place in a workplace scheme.

Illustration of a seamless NeviTec light panel ceiling above an executive boardroom table

Why the ceiling comes first

Sound in an open-plan office travels two ways: directly from the talker, and by reflection from hard surfaces. Screens, furniture and soft finishes deal with the direct path at desk height. The ceiling deals with the reflected path across the whole floor. Treat it poorly and no amount of soft furnishing will recover speech privacy; treat it well and every other measure works harder.

Ceiling absorption lowers the reverberation time of the space, which is the metric most briefs start from. It also shortens the distance at which a neighbouring conversation stops being intelligible, which is the quality occupants actually notice.

What to specify against

There is no single statutory acoustic standard for offices in the way BB93 governs schools, so the target is normally set by the brief, the landlord's specification or the acoustic consultant. The usual reference points are:

  • Reverberation time. Set per space type by the acoustic consultant, often informed by BS 8233 and the BCO Guide to Specification.

  • Open-plan metrics to BS EN ISO 3382-3. Spatial decay of speech (D2,S) and distraction distance (rD) describe how quickly speech fades with distance from the talker. Both respond strongly to ceiling absorption.

  • Sound absorption class to BS EN ISO 11654. Class A (highest) to Class E, derived from the weighted coefficient αw. This is the number a datasheet should give you, tied to a tested build-up.

  • BREEAM. Where the project is assessed, ceiling absorption contributes to the acoustic performance credits. It does not achieve them on its own.

Four ways to put absorption overhead

System

Format

Build-up

Absorption

Best suited to

Polyester acoustic stretch

Wall-to-wall seamless membrane

Fabric membrane over 50 mm polyester absorber; 55 mm total tested height

Class A, αw 1.00 (BAE 14-321-01)

Continuous ceilings where depth is tight

PVC micro-perforated acoustic stretch

Wall-to-wall seamless membrane

Micro-perforated PVC over absorbent foam; tested with a 490 mm frame void

Class B, αw 0.85 (Eurofins EUFI29-25003575-T1-EN)

Smooth technical finishes and wipe-clean areas

Sylo iC55 and iC37

Frameless horizontal rafts or wall panels

55 mm frame, 50 mm core (iC55); 37 mm frame, 30 mm core (iC37)

Class A, NRC 0.90

Open-plan zones and meeting rooms under exposed soffits

Baff iCs and iCl

Vertical suspended baffles

55 mm profile, 50 mm high-density core, absorbing on both faces

Request datasheet values for your layout

Atriums, exposed services and skylights; iCl adds LED

Wall-to-wall acoustic stretch

A stretch membrane spans the room from perimeter profile to perimeter profile, so the ceiling reads as one calm plane with no grid, joints or visible fixings. Behind it sits an absorbent core, and the membrane choice decides the performance:

  • Polyester acoustic stretch reached Class A, αw 1.00, in a total construction height of 55 mm when tested to BS EN ISO 354. For an office with a shallow void or a tight floor-to-ceiling height, it is the most depth-efficient way we know to put Class A absorption across an entire ceiling.

  • PVC micro-perforated acoustic stretch achieved Class B, αw 0.85, in its tested build-up. Choose it where a smoother, more technical surface or a wipe-clean finish matters more than the last increment of absorption.

Either way, the result is a monolithic ceiling that hides absorption completely: valuable in reception floors, boardrooms and client-facing spaces where the architecture must stay quiet visually as well as acoustically. See office acoustic ceilings and the polyester acoustic stretch system.

Sylo rafts: iC55 or iC37

Where the soffit stays exposed, as in many Cat B fit-outs, Sylo rafts put Class A absorption exactly where it is needed without closing the ceiling. Each panel is a rigid frame wrapped in Ecophon acoustic fabric, cable-suspended for a floating look or fixed tight with torsion-spring hardware. iC55 carries a 55 mm frame and 50 mm high-density core; iC37 drops to a 37 mm frame and 30 mm core for low-ceiling floors where every millimetre of headroom is argued over. We compare them in detail in Choosing between iC55 and iC37.

Rafts work best concentrated over the noisiest zones (collaboration areas, circulation routes and desks nearest to meeting rooms) rather than spaced evenly as a decorative pattern.

Baff when the soffit has to stay open

Vertical Baff baffles intercept sound travelling across the room rather than treating the ceiling plane. They suit atriums, cafés and breakout floors with skylights, sprinkler mains or ductwork that cannot be covered. Because both faces absorb, they deliver a large absorbent area for a small plan footprint. Baff iCl adds flush bottom-edge LED lighting, so the acoustic and lighting layouts become one gesture rather than two competing grids.

Meeting rooms: light and absorption in one plane

Meeting-room ceilings are crowded: downlights, detectors, diffusers and AV all compete with acoustic treatment. NT100A combines a uniform LED light panel with an acoustic core behind a tensioned diffuser in a 100 mm profile, with a choice of polyester or micro-perforated PVC membrane. One luminous, absorbent plane replaces a patchwork of fittings and tiles, and video calls benefit from even, shadow-free light. Ask us for build-up-specific acoustic data when you specify it.

Reading the data honestly

Two cautions save problems at tender stage:

  1. An absorption class belongs to its tested build-up. αw 1.00 for polyester acoustic stretch applies to the 55 mm construction tested. A thinner absorber or a different mounting will absorb less, so never transfer a certificate figure into an NBS clause for a different construction.

  2. Class is not coverage. A Class A product over 40% of the ceiling can do less than a Class B product wall to wall. The acoustic consultant's model, not the datasheet alone, should set the area.

We quote the certificate reference against every certified figure so your consultant can check it, and we say plainly where a value is a datasheet figure rather than an independent test.

Fit-out coordination checklist

  • Confirm the void depth and the deepest service it must clear before choosing between stretch, rafts and baffles.

  • Set out sprinkler heads, detectors and diffusers against the raft or baffle layout early. Sylo and Baff hang between services; stretch ceilings accept them through reinforced openings.

  • Agree the lighting strategy at the same time. Integrated LED in Baff iCl, NT100A or perimeter lines avoids pendants clashing with acoustic elements.

  • Check suspension points against the structure, particularly on post-tensioned slabs.

  • Plan maintenance access to valves and dampers. A stretch membrane can be demounted and re-tensioned by a trained installer.

  • Ask for the warranty in writing. Every NeviTec installation carries a 10-year warranty.

FAQ

Which office acoustic ceiling panel has the highest absorption class?

Class A is the highest class under BS EN ISO 11654. NeviTec's polyester acoustic stretch achieved Class A, αw 1.00, in a 55 mm tested build-up, and Sylo panels are rated Class A, NRC 0.90.

Can an acoustic ceiling meet BREEAM on its own?

No. Ceiling absorption contributes to the room's acoustic performance and to BREEAM acoustic credits, but the outcome depends on the whole room: finishes, layout and building services.

Rafts or a full acoustic ceiling?

Rafts (Sylo) or baffles (Baff) suit exposed-soffit schemes and targeted treatment. A wall-to-wall acoustic stretch ceiling suits spaces where a seamless finish and the maximum absorbent area matter most.

Where are NeviTec acoustic products made?

In Wellingborough, Northamptonshire. Manufacturing in-house keeps lead times short and lets our technical team support the specification directly.

Specify with the people who make it

If you are setting the acoustic strategy for an office fit-out, send us the drawings and the acoustic brief. We will propose a system, build-up and layout, with the test references to support it. Email hello@nevitec.com, call 07450 061429, or request a quote through our contact page. Contractors and fit-out firms can also apply to the NeviTec Trade Programme.

Comments


bottom of page